AngE ABI+

Arterial and Venous Screening in 1 Minute

🇦🇹 Made in Austria

AngE ABI+ Folder – 493.35 KB

Request a Presentation Shop

Detect early signs of vascular disease — even in patients with no symptoms

Prevent amputations and other Cardio Vascular Diseases (CVDs) – the world's leading cause of death.

Automated Vascular Screening in 1 Minute

Accurate, even with high blood pressure or stiff arteries.

macOS  and Windows  compatible.

Request a Presentation

Arterial Screening

Peripheral Artery Disease – PAD

Early detection of PAD and Diabetic Foot, independent of arterial stiffness.

Learn about Arterial Screening

Venous Screening

Chronic Venous Insufficiency – CVI

Hemodynamic assessment of CVI in 3 minutes.

Learn about Venous Screening

Available Test Protocols

Included or extendable measurement methods.

Vascular Screening

ABI, TBI, PWI™ and Score

ABI

Ankle Brachial Index Test

TBI

Toe Brachial Index

CVI

Chronic Venous Insufficiency

Toe Pressure

Systolic Toe Pressure

Erectile Dysfunction

PBI – Penile Brachial Index

Segmental

Segmental Oscillography

Raynaud's Syndrome

Morbus Raynaud Test

TOS

Thoracic Outlet Syndrome

Stress Test

Exercise ABI Screening

Allen's Test

Palmar Arch Test

Finger Flow

Microcirculation

Toe Flow

Microcirculation

Add Custom Tests

Protocols and Report Templates

Vascular Health Score New

Easy Interpretation for Anyone

The AngE™ ABI+ automatically calculates a Vascular Health Score, combining multiple parameters into one easy-to-read result. It is a standardized score that supports early detection and patient engagement.

Vascular Health Score is an optional add-on requiring an SOT Cloud account with a recurring subscription and internet access.

Get a Free Introduction

Clinical Applications

Atherosclerosis PAD – Peripheral Arterial Disease Limb Ischemia Arterial Stiffness IAD – Interarm Blood Pressure Differences Diabetic Foot / Ulcera Arhythmic Heartbeat / Arrhythmia TOS – Thoracic Outlet Syndrome Raynaud’s Syndrome CVI – Chronic Venous Insufficiency

Why Clinics Choose AngE™ ABI+

More about how Clinics offer Vascular Screenings >

High Patient Acceptance

Non-invasive, painless, and fast — ideal for preventive check-ups.

Multiple Parameters

ABI, PWV, PWI™, PVR, TBI, and more for a complete vascular profile.

Pay-Per-Use Model

No large upfront investment and usage-based billing, for ROI from day one. Learn more >

One-Page PDF Report

Branded with your clinic logo for patient records and referrals.

Upgrade Anytime

Two additional optical PPG probes to determine Toe-Brachial-Index – TBI, systolic Toe Pressure, Skin Temperature and Venous Function.

Works with Your System

The AngE Software supports DICOM and HL7 and works natively both on macOS  and Windows  computers.

Micro- and Macrocirculation

Assess the Micro- and Macrocirculation to estimate the Wound Healing success.

Stress Tests

Record the patients' blood circulation after passive and active stress tests, such as knee bends and toe tip stands, for effective clarification.

Key Benefits

Time-Saving

Complete vascular screening in 1 minute — versus ~10 minutes with Doppler ABI or ~20 minutes with TcpO₂.

Accurate

Simultaneous cuff measurement of all vessels and collaterals for greater precision than single-vessel Doppler tests.

Simultaneous

Instant left–right comparison to detect even the smallest differences in timing and amplitude.

Standardized

Consistent, repeatable results with reduced human error — no specialist training required.

Vascular Screening

Combine ABI, TBI and PWV

AngE™ ABI+ combines four measuring cuffs and two optical sensors to enable the measurement on six measuring spots simultaneously. This creates diverse possibilities to detect blood flow disorders within the terminal vessels as well as to assess the wound healing success of diabetic patients.


The innovative TOPP method was developed in collaboration with:

Prof. Dr. Georg Horstick

Practice for Vascular and Cardiac Medicine

ABI Standard Test

Simple and fast 4-cuff ABI test

The oscillometric ABI test provides a variety of parameters in a fast and non-invasive protocol, independent from stiff arteries.

Toe Pressure and TBI

Determine systolic toe pressure and Toe-Brachial-Index

Use toe cuffs and optical PPG sensors to accurately assess systolic toe pressure.

Venous Function Test

Check for CVI – Chronic Venous Insufficiency and Venous Valve Incompetence

The 2-minute hemodynamic test provides functional insight and is an established addition to imaging.

We have been using the AngE ABI+ system for several weeks now and are extremely satisfied. The examination is quick and straightforward, integrates seamlessly into our workflow, and provides a wide range of important vascular parameters in a clear and patient-friendly report. We highly recommend it for preventive medicine and cardiology applications.

Prof. Dr. med. Axel Preßler
Fellow of the European Society of Cardiology

A highly effective, easy-to-use system that performed exceptionally well in practical testing and is particularly useful in general practice, especially when determining further treatment options and differential diagnoses.

Dr. Maria Korak-Leiter
General practitioner and spokesperson for private practitioners in Carinthia

The semi-automated vascular screening with the AngE™ AngioExperience is after more than 150 years a long overdue replacement of simple doctors blood pressure recordings. By simultaneous recordings of pressure, pulse and ECG signals and their mathematical computations individual vascular functions can be assessed beyond an epidemiological cardiovascular risk assessment.

Prof. Dr. Dieter Magometschnigg
Founder of the Hypertension Research Institute

The high sensitivity of the optical sensors allow for a good documentation of the pulse waves, even with marginal blood flow. Given the virtually unfiltered display of pulse curves, dicrotic waves can be clearly identified for healthy and elastic arteries.

Dr. Alfred Obermayer
Head of Institute of Functional Phlebologic Surgery, Karl Landsteiner Society

Scientific Publications

"Time consumption for testing was significantly lower using the semiautomated AngE-device – a finding that is economically important, especially in high volume centers and epidemiologic studies."
– Mayr, Hirschl, Klein-Weigel, Girardi, Kundi; 2019

Diagnostic accuracy of ABI by Doppler versus Oscillometry.pdf – 556.78 KB

"Tissue optical perfusion pressure: a simplified, more reliable, and faster assessment of pedal microcirculation in peripheral artery disease."
– Horstick, Messner, Grundmann, Yalcin, Weisser, Espinola-Klein; 2020

TOPP: a simplified, more reliable, and faster assessment.pdf – 7.65 MB

Request a Presentation

Submit the form and an SOT expert will be in contact shortly.

* Sources:
World Health Organisation, 2014;
AHA – American Heart Association, "Asymptomatic Peripheral Arterial Disease Is Associated With More Adverse Lower Extremity Characteristics Than Intermittent Claudication", 2007

Vascular Health Score is an optional add-on requiring an SOT Cloud account with a recurring subscription and internet access.

References

1. Automated oscillometric blood pressure and pulse-wave acquisition for evaluation of vascular stiffness in atherosclerosis. (Massmann et al. 2017)

2. Diagnostic Accuracy Study of an Oscillometric Ankle-Brachial Index in Peripheral Arterial Disease: The Influence of Oscillometric Errors and Calcified Legs. (Herráiz-Adilo et al. 2016)

3. Interrater and intrarater reliability of photoplethysmography for measuring toe blood pressure and toe- brachial index in people with diabetes mellitus. (Scanlon C. et al. 2012)

4. Photoplethysmography detection of lower limb peripheral arterial occlusive disease: a comparison of pulse timing, amplitude and shape characteristics. (Allen J et al. 2005)


Trusted by 2,500+ customers worldwide

38 Years of
Vascular Experience

With more than 4,000 installations in more than 16 countries, SOT secures its position as knowledge leader in vascular diagnostics. We have made our knowledge available on:

Excellent Support
in 60 Seconds

Our product experts in Austria will help you with remote support without any waiting time or ticket system. Call us during office hours and we will help you within 60 seconds.

+43 4227 84 991

Mo - Th: 8am - 5pm, Fr: 8am - 12am

Made in
Austria 🇦🇹

We develop and produce our AngE™ products in Austria, where we adhere to the highest quality standards (ISO 13485:2016) and invest in our leading vascular diagnostic systems.


More Solutions